Tank Inventory Review for Endress+Hauser NMT81-154U90 Prothermo average temperature probe

description:Endress+Hauser NMT81-154U90 Prothermo average temperature probe for tank inventory monitoring, configured replacement and tank gauging integration review....
BASIC INFO

Using Endress+Hauser NMT81-154U90 Prothermo average temperature probe in Tank Gauging Projects

Endress+Hauser NMT81-154U90 Prothermo average temperature probe is a configured NMT81 reference for storage-tank temperature measurement and inventory applications. NMT81 can measure average product temperature and, with the appropriate option, provide water-bottom information.

Listed configuration

Primary project referenceNMT81-154U90
Extended codeNMT81-BBTAAMFEB0ABA1B1NB00EBEQJ00
Product familyProthermo NMT81
Measuring principleMultiple resistance temperature detectors
Typical system roleAverage tank temperature and inventory monitoring
Selection basisComplete code plus tank and gauging-system data

Tank gauging role

The Prothermo NMT81 family is designed for precise average temperature measurement in tanks and can integrate with systems such as Proservo NMS80-series devices, Micropilot NMR81/NMR84 and TankSideMonitor NRF81. Up to 24 RTD elements and redundant sensor processing are available at family level, depending on configuration.

Published family references

  • Average-temperature accuracy reference: ±0.032 °C with five-point calibration.
  • Maximum immersion length on request: up to 100 m.
  • Multiple temperature-range options, including cryogenic and elevated-temperature versions.
  • Optional continuous water-bottom measurement using a capacitance sensor.
  • Corrosion-resistant process parts and hazardous-area approvals are available by configuration.

These are NMT81 family capabilities. The exact sensor length, number of elements, spacing, process connection, approval and water-bottom option for Endress+Hauser NMT81-154U90 Prothermo average temperature probe must be confirmed from the order code and nameplate.

Information needed for replacement

Provide tank height, installation nozzle, required immersion length, element arrangement, process temperature, hazardous-area classification, connected tank-gauging equipment and current nameplate photographs. For custody-transfer work, also state the required metrology and calibration documentation.

Buyer note

Keeping NMT81-154U90 together with NMT81-BBTAAMFEB0ABA1B1NB00EBEQJ00 in the RFQ helps prevent a probe with the wrong length or sensor arrangement from being selected.

Official Endress+Hauser Prothermo NMT81 information.

Pre:Remote-Transmitter RFQ for Endress+Hauser 8F5B1H-RQF5/0 Promass F 500 Coriolis mass flowmeter Next:Endress+Hauser TM131-LPDD0/101 iTHERM ModuLine thermometer for Industrial Temperature Points